Single-camera optical strain measurement
ARAMIS 2D DIC
See in-plane strain and displacement across a specimen, without attaching a contact extensometer.
ARAMIS 2D uses one 12 MP camera to follow a prepared surface during a controlled test. Measure extension, strain localisation and movement within the image plane, with a practical route into optical materials testing and an upgrade path to stereo 3D.

The visible surface, measured through the test
What does ARAMIS 2D measure?
A camera records a high-contrast surface pattern before and during loading. Digital image correlation follows that pattern through the image sequence and calculates in-plane displacement and surface strain. Point tracking can follow selected features where a continuous strain field is not required.
Use full-field maps to see where deformation concentrates, place virtual extensometers across selected gauge lengths, and compare movement at several locations from the same recording.

From setup to an engineering result
Four ways to get more from a planar test
Build the optical measurement around the in-plane movement, local strain and stages that matter to your result.
Keep the optical setup simple
A single camera provides a direct view of a flat specimen. Choose the lens, working distance and illumination around the area you need to evaluate. Position the camera approximately normal to the measurement plane and check focus across that region.
See more than one extension value
Evaluate the distribution of in-plane strain instead of relying on one average reading. Compare virtual gauge lengths and identify necking, a notch effect or another local concentration. Keep evaluation direction, gauge length and spatial averaging consistent when comparing specimens.
Follow the test through to failure
Non-contact measurement avoids attaching an extensometer directly across the region of interest. A suitable recording can retain the stages before and around failure, provided the pattern remains visible and the acquisition rate captures the behaviour of interest.
Build a route to stereo 3D
A compatible 2D setup can form the starting point for an Adjustable 12M stereo system. An upgrade adds the required second camera and compatible mounting, optics, calibration and software arrangement. Define that future requirement with Delta XD when selecting the initial system.
Typical ARAMIS 2D applications
Flat specimens and in-plane strain
Choose the view and evaluation around the part of the test that needs to be understood.

Tensile, shear and flat-specimen tests
Measure in-plane extension and strain on flat coupons and laboratory specimens. Compare different parts of the gauge section, follow a developing neck or examine how strain changes around a notch or geometric transition.
Shear and other loading arrangements can be suitable when the evaluation area remains in a controlled plane. Plan the fixture and grips to avoid rotation, buckling or movement towards and away from the camera. The photograph illustrates an optical materials-test arrangement; the camera configuration is specified for your application.

Strain localisation and virtual extensometers
Investigate whether the visible deformation is uniform or concentrated around a hole, edge or other feature. Place virtual extensometers and strain evaluations where they answer the measurement question, then review the corresponding stages through the test.
A strain map does not supply every quantity needed for a material property. Combine the optical result with suitable force and specimen geometry data for stress–strain calculations. Use appropriate procedures and validation for any standards-based result.
A laboratory setup built around the test
Build the 2D setup around the measurement plane
The camera, metrology lens, mounting and illumination work together. Select a view that covers the complete evaluation area while keeping enough pixels on the smallest feature or strain concentration of interest. Prepare a suitable speckle pattern and check image contrast before the principal test.
Planarity is central to 2D DIC. Movement through depth changes the apparent size of the surface in the image and can affect the in-plane result. If the specimen bends out of plane, twists, buckles or has a curved measurement surface, discuss stereo 3D rather than assuming the single-camera arrangement will answer the question.
The quotation defines the camera, lens, calibration equipment, lighting, workstation and software scope. The ARAMIS Controller is an optional extra, not standard equipment.
- Single-camera imaging1 × 12 MP camera with 4096 × 3000 pixels for in-plane measurement.
- Optics and mountingSelect the lens and working distance for the measuring area and practical fixture access.
- Calibration and verificationUse the appropriate procedure for the selected optics and measurement arrangement.
- Blue LED illuminationChoose suitable lighting for the surface, exposure and field of view. B45-15 illumination options can be configured around the test.

Optional test synchronisation
Optional synchronisation with the ARAMIS Controller
The ARAMIS Controller is available as an optional extra when the 2D measurement needs to be synchronised with the test setup. It is not included as standard with the ARAMIS 2D system.
With the appropriate configuration, use it to coordinate image acquisition with supported force, stroke or other external signals. This helps relate the optical displacement or strain to the applied loading at the corresponding stage of the test.
Specify the signal interface, trigger source, timing and recording sequence with Delta XD. The test machine or external instrument supplies the signal; the Controller acquires the supported input. Include the Controller in the quotation when this synchronisation is required.
Explore the optional ARAMIS ControllerMeasurement and analysis software
Evaluate the test in CORRELATE
Turn the recorded sequence into displacement, strain and movement results. Review the full field, place virtual extensometers and relate local behaviour to the stages of the test.
Choose the licence around your data, analysis and reporting workflow. ARAMIS acquisition requirements are configured alongside the sensor.
Explore CORRELATE software and licences
Entry-level evaluation
CORRELATE Free
Non-parametric evaluation of 2D images and videos for DIC, point tracking and reporting, with mesh and basic CAD imports. Combined with an ARAMIS system and sensor driver, it is CORRELATE Essential Line.
Repeatable commercial analysis
CORRELATE Pro
Record evaluation steps and their dependencies in a parametric project. Reuse project templates, customise reports, work with supported native CAD formats and extend analysis through apps, Python scripting and supported data exports.
Academic and research use
CORRELATE Education
The analysis functionality of CORRELATE Pro for eligible academic and research users, exclusively for non-commercial work. Discuss institutional eligibility and the intended research activity with Delta XD when requesting a licence.
Advanced ARAMIS acquisition
CORRELATE Pro Line
Add supported live tracking, ring-buffer acquisition and triggering from external signals such as force. Pro Line also supports an optically tracked touch probe and adapters. Acquisition functions, sensor compatibility and accessories are configured separately.
Education is restricted to eligible non-commercial academic and research use. Pro Line acquisition, touch probes and hardware options are specified separately; they are not implied by an Education or Pro analysis licence.
Choose around the measurement question
When should you choose stereo 3D instead?
Choose 2D when a controlled in-plane arrangement answers the measurement question. Choose stereo 3D when movement through depth matters, the surface is curved, or the complete three-dimensional response is needed.
ARAMIS Adjustable 12M

The modular stereo upgrade route for a broader range of specimens and measuring areas.
Explore ARAMIS Adjustable 12M →ARAMIS 1

For focused stereo 3D measurement of materials and small components.
Explore ARAMIS 1 →ARAMIS Adjustable SRX

For faster dynamic events, with frame size, onboard memory and recording duration matched to the test.
Explore ARAMIS Adjustable SRX →Technical data
ARAMIS 2D specifications
| Measurement principle | Single-camera digital image correlation and point tracking |
|---|---|
| Camera arrangement | 1 × 12 MP camera for in-plane measurement |
| Camera resolution | 4096 × 3000 pixels |
| Full-resolution acquisition | Up to 25 fps at 4096 × 3000 pixels |
| Reduced-image acquisition | 43 fps at 2496 × 2096 pixels; 75 fps at 4096 × 1000 pixels; 150 fps at 4096 × 500 pixels (1/6th image) |
| Binning mode | Up to 100 fps at reduced spatial resolution |
| Measuring-area range | Approximately 20 × 15 mm to 5000 × 4000 mm across different optical configurations |
| Measured movement | In-plane displacement and surface strain; depth movement is not measured |
| Test synchronisation | Optional ARAMIS Controller for supported image-synchronous external signals; not standard equipment |
| Software | CORRELATE Essential Line included in the displayed system package; Pro and Pro Line options specified separately |
These data describe the 12M single-camera configuration. Maximum rates depend on image dimensions, acquisition mode and the configured hardware. Reduced-image modes retain less of the sensor area; binning reduces spatial resolution. Measuring-area limits describe different optical setups, not one fixed arrangement.
ARAMIS 2D questions, answered
Plan the measurement before the test
What is the difference between 2D and 3D DIC?
2D DIC uses one camera to measure displacement and strain within a plane. Stereo 3D uses two calibrated views to measure three-dimensional surface coordinates and movement. If depth movement is significant, the single-camera result can be affected and stereo 3D may be the appropriate choice.
What is ARAMIS 2D used for?
Typical uses include quasi-static tensile tests, shear tests on flat specimens, virtual extensometers and local strain investigations. Other tests can be suitable when the visible evaluation area remains planar and the images retain enough detail throughout loading.
Is the ARAMIS Controller included as standard?
No. It is an optional extra for synchronising image acquisition with supported external test signals. Specify it in the quotation if force, stroke or another signal must be acquired synchronously with the optical measurement.
Can I measure strain without a contact extensometer?
Yes. A suitable speckle pattern allows the camera to follow the visible surface without a contact extensometer on that region. Virtual extensometers and full-field strain maps can be evaluated from the recording. The setup, image quality and evaluation method still need to suit the measurement requirement.
Can ARAMIS 2D produce a stress–strain curve?
The optical measurement provides strain or extension. Calculating stress also needs suitable force and specimen geometry data. If those data must be synchronised with the images, include the optional Controller and compatible interfaces in the measurement plan.
What frame rate is available?
The 12M configuration records up to 25 fps at 4096 × 3000 pixels. Reduced-image modes reach 43 fps at 2496 × 2096, 75 fps at 4096 × 1000 and 150 fps at 4096 × 500 pixels. Binning can provide up to 100 fps at lower spatial resolution.
Can it measure bending or out-of-plane movement?
It can evaluate a visible planar region in an appropriate bending arrangement, but it does not directly measure movement through depth. If that region moves out of plane or rotates significantly during loading, use a suitable stereo 3D system to capture the three-dimensional response.
Can I upgrade ARAMIS 2D to an Adjustable 12M 3D system?
A compatible 2D configuration has an upgrade route to stereo Adjustable 12M. The required second camera, optics, mounting, calibration equipment, software and commissioning are specified as an upgrade package. Discuss the intended future measuring areas when choosing the initial configuration.
How much does an ARAMIS 2D system cost?
Systems start from £9,857*. The package includes a lens, calibration object, tripod, camera mount and CORRELATE Essential Line software. Laptop/computer, ARAMIS Controller, delivery and training are excluded. Add the optional Controller when synchronisation with supported external test signals is required.Excluding VAT
System pricing
Start with the planar test you need to run
Discuss specimen size, expected in-plane movement and the local detail you need to resolve. Include any movement through depth so Delta XD can assess whether 2D or stereo 3D is the better fit.
Tell us if external force, stroke or other signals need to be synchronised with the images. We will specify the optional ARAMIS Controller where required.
ARAMIS 2D system from£9,857*Excluding VAT
Request a configured quotationSystem price from £9,857. Includes a lens, calibration object, tripod, camera mount and CORRELATE Essential Line software. Excludes laptop/computer, ARAMIS Controller, delivery and training. The ARAMIS Controller is available as an optional extra for test synchronisation.Excluding VAT
*Indicative starting price for the stated configuration, excluding VAT and subject to change. Final pricing and system specification confirmed by quotation.
Product and software information
ARAMIS 2D product and software downloads

12M platform one-pager
Camera and acquisition data for the Adjustable 12M platform, including the option for a 2D setup. Request the exact single-camera configuration in your quotation.
Download PDF →
CORRELATE software factsheet
Measurement, evaluation and reporting capabilities for optical testing workflows.
Download PDF →
ARAMIS product brochure
Explore the wider range of optical strain and deformation measurement systems.
Download PDF →Talk to Delta XD
Tell us what you need to measure
Ask for an ARAMIS 2D quotation, discuss a demonstration or review the setup for a planned materials or component test.
Include the specimen size, measuring area, expected movement and the smallest feature or strain gradient you need to resolve. Tell us whether synchronised force or other external signals are needed so we can specify the optional Controller.